Jump to content

InGodWeTrust

Members
  • Posts

    55
  • Joined

  • Last visited

Required Information

  • FirstName
    William
  • Make
    Monaco
  • Model
    Windsor PWD
  • Year
    2003
  • City & State
    Titusville, Florida

Optional Information

  • Full Address (Optional)
    375 Plantation Dr., Titusville, Florida, 32780

Recent Profile Visitors

227 profile views

InGodWeTrust's Achievements

4

Reputation

  1. Thank you so much Rick that is exactly what I needed apparently didn't read that part but, to be honest I still wouldn't have figured out without your color depiction. Xantrex support did also include blue wire in connection connected to pin 12 and pin 13 tied into pin's 16 and 18. Anyhow thank you so much for all your help truly appreciate all your help. Kind Regards, Thank you everyone for your input finally got it squared away. For anyone connecting AGS from a rv2012 to a sw3012 this is the breakdown. Genset Green-pin 14 "" Brown- pin 16,18,13 "" Red- pin 17 "" Blue- pin 12 Hope this helps.
  2. Yes, this diagram was a big help my issue is on the AGS side of the connection not sure which gen start/run to connect. Diagram shows 3 relay 1's open, closed, and common so, according to pdf I believe that would be the brown wire. Which relay should I connect this to?
  3. That does make sense forgot about switch inside bedroom. Did you have same colors? Red, green, & brown, blue was not connected.
  4. Thanks for pdf not sure why they have 2 greens, 2 reds, and 2 browns coming from generator on my onan 7.5 qd.
  5. Thanks Tom, I tried pulling up documentation from Onan 7.5 QD HDKA but nothing that references wiring schematic need to dig further. As for AGS system it's the newer AGS connected via xanbus 809-0915. I really cringe with the possibility of crossing wires hopefully Xantrex tech support can help.
  6. Any insights would help. Replaced rv2012 inverter with sw3012 all went well except currently hung up on wiring for AGS 20 point connecter. 2012 only utilized 3 of the four incoming wires green, brown, red labeled gen run 1& 2; gen start 1 & 2. Green wire (gen run 2) was pigtailed into 2 green wire wing nut, 1st brown wire (gen run 1) 2nd brown (gen start 1) all tied into brown incoming feed. Red (gen start 1) pigtailed into incoming red feed. Blue (not used) not sure what this is? Anyhow these are the photos any help is greatly appreciated. Thanks in advance
  7. Hi Tom, Thanks for digging in further. I finally got it squared away apparently when I attached romex connector in all my effort wrangling 10ga wire I must have exposed wire from rubbing on casing so L2 was making contact with metal therefore shorting itself out. Whew glad surgeprotector kicked in. Again thanks for all your help greatly appreciated let me know if I can ever return the favor. Kind regards, Will Update: Inverter confusion finally sorted out had some bare wire making contact causing the short. Thanks to everyone for your help and insights greatly appreciated. I will now be attempting to install AGS seems like old Trace only utilized gen run and gen start features so hopefully I can decipher all this.
  8. Thank you very informative. Wish they would continue producing more videos. So, started new sw3012 install yesterday, but ran into an issue on the AC side. What I found is two feeds coming from panel each is a 10 gauged 1 black (load) and 1 neutral, 1 ground. The problem I'm having is sw3012 on the incoming side 1 neutral, L1, and L2 and of course ground bus bar not sure what to do with L2 neutral anyone run into? This is how feeds came off old inverter.
  9. Thanks Tim, looked at that option seemed like install would have been too involved with my limited knowledge. I was looking for plug and play option and since Trace is now Xantrex thought this would be the best match but from what I'm told Magnum is a closer replacement. Anyhow, already purchase and looking to install tomorrow weather permitting (Little Rock, AR). Thanks for feedback Thanks Tom, Wish I would have dug in further into adequate replacement. My first assumption was Trace now Xantrex that sw3012 would be the best option especially since dual in and out. I did purchase remote adapters for remote and AGS thought about combox but will have to wait and see if I really need that functionality. Where should 4/0 ground wire go with new 3012? I've seen some put this directly with negative connection. Thanks
  10. Has anyone swapped out Trace rv2012 for Xantrex sw3012 inverter? Seems straight forward the only hang ups I can foresee is old tracer had a 4/0 ground attached to inverter new 3012 does not have connection point. Second is getting AGS (auto gen set) properly configured to generator mainly the 20 point connecting wiring do colors on current Trace correspond to new 3012? Any help with this is greatly appreciated.
  11. Hey Mark thanks for info replacing rv2012 for sw3012 what did you do with ground on old trace.
  12. We have been using nomad internet (the works anywhere plan) great unlimited plan no throttling.
  13. Richard, Sounds like a worthwhile visit you should feel much safer going down the interstate. Let me know if you can come up with something for HWH Compressor that's a great idea mine was just sitting without anything to hold it down I wondered why it made so much noise every time it kicked on (vibration) took some zip ties to strap it down as a temporary fix.
×
×
  • Create New...