Jump to content

grizzly

Members
  • Posts

    149
  • Joined

  • Last visited

Everything posted by grizzly

  1. Yea did that and same issue. I even took the thermostat up to roof and plugged directly into the board and had same issue. When you say swap boards do you mean the boards that are in the ac unit on the roof? Do you know if and where you can get a new one if needed Tom Cherry?
  2. Have done all you said and still have the issue. I even went to roof and plugged in thermosates control into each individual slot on the board and still have the same issue. So I assume there is an issue with my board? Thermostats are good and wiring is good. Swapped the thermostats and still same issue
  3. Thank you that solved that issue but I still have issue with front unit coming on when I turn switch to on and nothing turned on. Did everything Tom Cherry said and still have issue So I did everything and still have issue. Event when I took the thermostat to roof and plugged in the unit came on with nothing turned on except the off/on switch
  4. So I did everything and front unit still just comes on when turned on BUT now I have another issue.All of a sudden I have no power to either wall thermostats front or rear. Just all went dead. What could cause that? I am puzzled. Everything was working then bam nothing.
  5. So cleaned everything and tried switching control panel but still have problem. Will go up on roof next and see after rain stops Hope to solve issue up there
  6. Thank you I will do and let you know
  7. Have 07 Monaco Sig and when I turn on the wall controller for the front unit even if no mode is selected, the ac/heat pump comes on. If I switch to furnace mode the ac/heat pump stays on and furnace comes on. No matter what I do when ever I turn on wall controller from off to on the ac/heat pump comes on even if no mode is selected. I went up in the ceiling and changed the telephone ;ole cable connect over to the other one and that did t help . Is the controller no good or is there some other issue?
  8. I always look for Indian Casinos as they have the best prices usually then Costco but getting in and out with a big rig is hard sometimes. I am 45 plus tow so about 70
  9. We have been full time for 7 yrs and we only use water pump when not hooked up to city water or there is power outage and no water. But we also have been at 1 park for a very long time and the water is well water and very good so we don't worry as I take carry of the water system here. Very good water!
  10. Mine died and it was the solenoid. It is in front bay on passenger side on fire wall in my coach. Follow the air line is how I found it
  11. I had similar issue and once I cleaned the big boy all was good
  12. When I had a starting problem in the past what I did was go into the back engine bay and take my Big Boy off and clean it and never had an issue since then. That's what worked for my case
  13. Just have a question. Why do you use the macerator? We have one and I used it at first but takes to long to empty all the way. I just dump direct
  14. Yea mine has never brought it in so I bring it in before it works if it works. lol
  15. Ive never brought in my slides in wind and we have had gust up to 60 mph with sustained wind at 35-40 mph. But any awnings I bring in at 15-20 except my door awning which usually stays out except in extreme wind like 40 or above
  16. You know calif makes people pay according to income now.There are 4 tiers based on your income. You pay more so people with low income pay less and they penalize you if you conserve energy if you have higher income. New law passed. Not sure if it has been implemented yet
  17. is that PG&E ? We pay .16 KWH up in northern CA
  18. So it does work at all or does it just clogged up and won't spin? We have 2 in our 07 Sig. Ive taken them apart 3 times but the problem was it was clogged by too much TP each time.
  19. What was the reason they told you to replace them? A lot of folks replace them themselves. Bags can be found for various prices if you look on line. Front are easier to replace yourself than the rear ones. Many links on here about that.
  20. Could be that your compressor is worn out. That's what was going on with mine. Inside the cylinder was totally gone. Also check for leaks in lines.Turn to manual mode and see if coach settles or go out and listen for a leak. Are your tanks holding air?
  21. On lock issue try disconnecting batteries at cut off and then turn back on. We count get front door unlocked and this solved the issue Washing machine is probably the drain pump is shot, that's what happened to ours
  22. I believe there has been topics and how to on o ring replacement and cleaning of solenoids on here. Just look it up. Great info. Had problem with my air system and between guys on here and valid I got it resolved
  23. So sorry to hear. Prayers sent you way for both of you
  24. We have a Tecma. Works fine only problem was I plugged it up one time with too much paper. Had to pull it out and clean out the paper in the emaciator part of it. Easy to do.
  25. Thanks. Did it today and that solved the issue.Just had to reset the thermostat and it worked the way it should. Problem solved Thank you
×
×
  • Create New...