Will do. Just looked at the ATS. Exactly as Tom described. Will order what Tom suggested and have it put in. Not plugging in until I have a properly dedicated line at home😂 thank you!
The current state of this section was reached in the 2008 NEC, which forbade new construction from using the feeder neutral to provide ground for the fed system. (Your choices now are to provide a separate ground wire, which is what is normally done, or use a distribution transformer to create a separately derived system for the fed building, which has its own N-G bond.) Many of the installations that fall under the current exception were installed prior to the 1999 NEC, which is the first edition that forbade parallel current paths between the structures involved.
Thank you. Going to run a dedicated port from the house to Coach.
Sure did! Had the fridge guy in today! Thank you!